• 丝瓜视频在线下载,丝瓜导航成人,丝瓜视频免费看黄网站,丝瓜视频成年APP下载观看

    Home

    Product

    New Energy Products

    Solution
    GTM6L series residual current circuit breaker
    Rated main circuit current
    Rated current
    The rated voltage
    Application
    ■ Protection function

    It features leakage protection, overload protection, and short circuit protection

    ■ Indication and adjustment of leakage parameters can be performed on the circuit breaker panel

    ■ The rated residual operating current and maximum interruption time can be adjusted according to the actual situation

    ■ Current ranging from 32A to 630A

    Technical specification
    Main Technical Parameters Table of GTM6L Leakage Circuit Breaker

    GTM6L-125:
    GB/T14048.2
    IEC60947-2
    Frame grade (Inm(A)): 125
    Operating frequency (Hz): 50
    Breaking type: L/M/H
    Number of poles: 3P 3P+N, 4P/3P 3P+N, 4P/3P 3P+N, 4P
    Rated current (In(A)): 32, 40, 50, 63, 80, 100, 125
    Rated insulation voltage (Ui(V)): 1000
    Rated impulse withstand voltage (Uimp(kV)): 8
    Rated operating voltage (Ue(V)): AC400
    Arcing distance (mm): ≯50
    Rated ultimate short-circuit breaking capacity (Icu(kA)): 25/35/50
    Rated operating short-circuit breaking capacity (Icu(kA)): 12.5/25/25
    Rated residual short-circuit making and breaking capacity (I△m(kA)): 25%Icu
    Rated residual operating current (I△n(mA)): 30 (only for non-time-delay type) 200, 300, 500 (time-delay type)
    Limit non-driving time/delay type (s): 0.1, 0.3, 0.5
    Rated residual non-operating current (I△no (mA)): I△no = I△n/2
    Optional category: A
    Service life: Mechanical lifespan (times) Maintenance-free: 10,000/Mechanical lifespan (times) Maintained: 20,000/Electrical lifespan (times): 4,000
    Outline dimensions (mm): width (W): 92/122/92/122/92/122, length (L): 150/150/150/150/150/150, (H): 98/98/98/98/115/155
    Mounting plate hole dimensions (mm): Width (A): 30/60/30/60/30/60, Length (B): 129/129/129/129/129/129, Diameter (φ): 5.5/5.5/5.5/5.5/5.5/5.5
    Optional accessories
    Alarm contact 08: □/□/□/□/□/□
    Shunt release 10: □/□/□/□/□/□
    Auxiliary contact 20: □/□/□/□/□/□
    Auxiliary contact + alarm contact 28: □/□/□/□/□/□
    Back-of-board wiring R: □/□/□/□/□/□
    Plug-in board rear wiring PR: □/□/□/□/□/□

    GTM6L-250:
    GB/T14048.2
    IEC60947-2
    Frame grade (Inm(A)): 250
    Operating frequency (Hz): 50
    Breaking type: L/M/H
    Number of poles: 3P 3P+N, 4P/3P 3P+N, 4P/3P 3P+N, 4P
    Rated current (In(A)): 125, 140, 160, 180, 200, 225, 250
    Rated insulation voltage (Ui(V)): 1000
    Rated impulse withstand voltage (Uimp(kV)): 8
    Rated operating voltage (Ue(V)): AC400
    Arcing distance (mm): ≯80
    Rated ultimate short-circuit breaking capacity (Icu(kA)): 25/35/50
    Rated operating short-circuit breaking capacity (Icu(kA)): 12.5/25/25
    Rated residual short-circuit making and breaking capacity (I△m(kA)): 25%Icu
    Rated residual operating current (I△n(mA)): 30 (only for non-delay type) 200, 300, 500 (delay type)
    Limit non-driven time/delay type (s): 0.1, 0.3, 0.5
    Rated residual non-operating current (I△no (mA)): I△no = I△n/2
    Optional category: A
    Service life: Mechanical lifespan (times) Maintenance-free: 10,000/Mechanical lifespan (times) Maintained: 20,000/Electrical lifespan (times): 4,000
    Overall dimensions (mm): width (W): 107/142/107/142/107/142, length (L): 165/165/165/165/165/165, (H): 100/100/100/100/118/118
    Mounting plate hole dimensions (mm): Width (A): 35/70/35/70/35/70, Length (B): 126/126/126/126/126/126, Diameter (φ): 5.5/5.5/5.5/5.5/5.5/5.5
    Optional accessories
    Alarm contact 08: □/□/□/□/□/□
    Shunt release 10: □/□/□/□/□/□
    Auxiliary contact 20: □/□/□/□/□/□
    Auxiliary contact + alarm contact 28: □/□/□/□/□/□
    Back-of-board wiring R: □/□/□/□/□/□
    Plug-in board rear wiring PR: □/□/□/□/□/□

    GTM6L-400:
    GB/T14048.2
    IEC60947-2
    Frame grade (Inm(A)): 400
    Operating frequency (Hz): 50
    Breaking type: L/M/H
    Number of poles: 3P 3P+N, 4P/3P 3P+N, 4P/3P 3P+N, 4P
    Rated current (In(A)): 250, 315, 350, 400
    Rated insulation voltage (Ui(V)): 1000
    Rated impulse withstand voltage (Uimp(kV)): 8
    Rated operating voltage (Ue(V)): AC400
    Arcing distance (mm): ≯100
    Rated ultimate short-circuit breaking capacity (Icu(kA)): 35/50/70
    Rated operating short-circuit breaking capacity (Icu(kA)): 25/35/505
    Rated residual short-circuit making and breaking capacity (I△m(kA)): 25%Icu
    Rated residual operating current (I△n(mA)): 300, 500, 1000
    Limit non-driven time/delay type (s): 0.1, 0.5, 1
    Rated residual non-operating current (I△no(mA)): I△no = I△n/2
    Optional category: A
    Service life: Mechanical life (times) Maintenance-free: 10,000/Mechanical life (times) Maintained: 20,000/Electrical life (times): 2,000
    Outline dimensions (mm): Width (W): 150/198/150/198/150/198, Length (L): 257/257/257/257/257/257, (H): 152/152/152/152/152/152
    Mounting plate hole dimensions (mm): width (A): 44/94/44/94/44/94, length (B): 194/194/194/194/194/194, diameter (φ): 7/7/7
    Optional accessories
    Alarm contact 08: □/□/□/□/□/□
    Shunt release 10: □/□/□/□/□/□
    Auxiliary contact 20: □/□/□/□/□/□
    Auxiliary contact + alarm contact 28: □/□/□/□/□/□
    Back-of-board wiring R: □/□/□/□/□/□
    Plug-in board rear wiring PR: □/□/□/□/□/□

    GTM6L-630:
    GB/T14048.2
    IEC60947-2
    Frame grade (Inm(A)): 630
    Operating frequency (Hz): 50
    Breaking type: L/M/H
    Number of poles: 3P 3P+N, 4P/3P 3P+N, 4P/3P 3P+N, 4P
    Rated current (In(A)): 400, 500, 630
    Rated insulation voltage (Ui(V)): 1000
    Rated impulse withstand voltage (Uimp(kV)): 8
    Rated operating voltage (Ue(V)): AC400
    Arcing distance (mm): ≯100
    Rated ultimate short-circuit breaking capacity (Icu (kA)): 50/70/100
    Rated operating short-circuit breaking capacity (Icu(kA)): 35/50/70
    Rated residual short-circuit making and breaking capacity (I△m(kA)): 25%Icu
    Rated residual operating current (I△n(mA)): 300, 500, 1000
    Limit non-driven time/delay type (s): 0.1, 0.5, 1
    Rated residual non-operating current (I△no(mA)): I△no = I△n/2
    Optional category: A
    Service life: mechanical life (times) maintenance-free: 10000/mechanical life (times) with maintenance: 20000/electrical life (times): 2000
    Overall dimensions (mm): width (W): 210/280/210/280/210/280, length (L): 280/280/280/280/280/280, (H): 158/158/158/158/158/158
    Mounting plate hole dimensions (mm): width (A): 140/140/140/140/140/140, length (B): 243/243/243/243/243/243, diameter (φ): 7/7/7
    Optional accessories
    Alarm contact 08: □/□/□/□/□/□
    Shunt release 10: □/□/□/□/□/□
    Auxiliary contact 20: □/□/□/□/□/□
    Auxiliary contact + alarm contact 28: □/□/□/□/□/□
    Back-of-board wiring R: □/□/□/□/□/□
    Plug-in board rear wiring PR: □/□/□/□/□/□
    Download
    點擊下載 附件:GTM6L漏電斷路器.pdf    大小: 37.88MB 下載:
    Leave a message
    Under construction...
    Committed to technological innovation
    Make electricity supply more reliable, make electricity use more secure.
    Product quotation consultation
    A free consultation
    hotline:400 8099 777

    CONTACT US

    WeChat

    Jubang science and technology park, wei16 road, leqing economic development zone, zhejiang province

    • phones:+86577 62799786
    • fax:+86577 62799771
    • Email:jubanggroup@163.com
    • web:www.5410086.com
    • Customer service hotline:400 8099 777
    網站地圖